SMAP-G2 HD MTP module cassettes 1/3 HE with 6/6 width partition, 8 fibres, LC-Duplex / MTP OCTO singlemode fitting for PreCONNECT® OCTO trunks

High quality SMAP-G2 HD MTP module cassettes 1/3 HE with 6/6 width partition, 8 fibres, LC-Duplex singlemode blue / MTP OCTO female singlemode APC green, polarity OCTO Rx to Tx, RAL 9005 black → ATTENTION: Please only use patch cord LCC-PPB!

€130.06 * (excl. VAT)

Delivery time within 1 weeks

Product number: 170H1101

SMAP-G2 HD 8 fiber MTP-LC module cassettes

Applications

  • For Port-Breakout of PreCONNECT® OCTO trunks with MTP® connectors
  • Fitting in SMAP-G2 HD panel with 6/6 width partition

Properties

  • 1x MTP® female port 4+4F OCTO at the rear side
  • 4 LC-Duplex ports at the front side
  • Toolless placement of the module cassettes into the panel from the front side, fixing with quick fasteners

Material and color:

  • Cassette body and front: aluminum powder coated RAL9005 black

Adapter types:

  • Rear side: 1 MTP®
  • Front side: 1 LC8 = 4 LC-Duplex ports

Adapter variants:

  • MTP® multimode: TIA type B „aligned centered keys“ „1 to 12“ grey
  • MTP® singlemode: TIA type A “opposed centered keys” „1 to 1“ green
  • LC8: OM4 violet, SM blue

Number of fibers:

8

Scope of delivery and packaging:

  • Module cassettes fully factory-assembled in carton
  • Adapters mounted
Breitenteilung: 1/6
Gehäuse:
Kupplung:
Kupplungsfarbe Rückseite: Green
Kupplungsfarbe Vorderseite: Blue
Kupplungstyp Rückseite: MTP® female Port 4+4F OCTO
Kupplungstyp Vorderseite: LC-Duplex
Polarität: Rx to Tx
Produktlinie: PreCONNECT® SMAP-G2 High Density (HD)
colour: RAL 9005
hight units: 1/3 HE

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Accessory Items

SMAP-G2 HD 19" 1HU empty distribution panels, RAL9005 black, back plane with 12 PreCONNECT® square interfaces, 6/6 widths partition, depth 300 mm
PreCONNECT® SMAP-G2 High Density (HD) 19” 1HU empty panel 6/6 width partition Applications Panel system for data center data cabling For all IT applications like Ethernet and Fibre Channel Appropriate for Spine-Leaf architectures, by default 12, optional up to 16 trunks coming from Leaf Switches can be accommodated per HU within SMAP-G2 distribution panels next to the Spine-Switch Properties Port density: 72 LC-Duplex or MTP® ports per height unit HU PFPs and cassettes are toolless inserted from the front side and fixed with quick fasteners PFPs and cassettes can be pulled out to the front for maintenance Through its adjustable 19“ mounting brackets the panel can be depth variable mounted Trunk cables can be routed into the panels through their back planes and either side At panels with trunk routing through their back planes, which are not fully equipped during their first installation, trunk cables can be retrofitted afterwards and removed for maintenance Front granularity 6/6 width partition Material and color: Panel body: aluminum silver 19“ mounting brackets and front: steel powder coated RAL9005 black Scope of delivery and packaging: Distribution panel fully factory-assembled in carton Blind cover in unused cable inputs

€95.78 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, CS-PC/CS-PC, I-V(ZN)H rund 2,0 mm, with CS EZ-Flip, 2,0m
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€30.80 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, LC-PC/LC-PC, I-V(ZN)H(ZN)H rund 4,0 mm, with LC Compact Push Pull Tab
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€20.48 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, LC-PC/LC-PC, I-V(ZN)H(ZN)H rund 4,0 mm, with LC Compact Push Pull Boot
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€20.38 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, CS-PC/LC-PC, I-V(ZN)H rund 2,0 mm, with CS EZ-Flip and LC Compact Pussh Pull Boot, 2,0m
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€29.07 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, CS-PC/CS-PC, I-V(ZN)H rund 2,0 mm, with CS EZ-Flip, 5,0m
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€31.40 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, CS-PC/LC-PC, I-V(ZN)H rund 2,0 mm, with CS EZ-Flip and LC Compact Pussh Pull Boot, 5,0m
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€29.00 (excl. VAT)
Fiber optic patch cord duplex singlemode OS2, LC-PC/LC-PC, I-V(ZN)H rund 2,0 mm, with LC Compact Push Pull Boot
Fiber Optic Patch Cords Applications Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request. Properties Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173 Half duplex cables with duplex/simplex connectors „uncrossed“ Duplex cables with simplex connectors on both sides „uncrossed“ Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable types: FRNC-LSZH cable, for more cable specifications see data sheet. Scope of delivery and packaging: Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length. Length tolerance: Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

€19.65 (excl. VAT)
Fiber optic trunk cable breakout 32 fibers singlemode OS2, MTP®-OCTO-PC-m/ MTP®-OCTO-PC-m, I-F(ZN)HH
PreCONNECT® OCTO MTP® Breakout Trunk cable Applications MTP® (MPO) based data center cabling with 8 fibers per MTP® channel. Optimized for parallel optics MPO 4+4 fiber applications: 40/100/200 GBASE-SR4 400GBASE-SR4.2 BiDi 4x16, 4x32 and 4x64 GFC 100GBASE DR4/PSM4 200GBASE-DR4 400GBASE-DR4 4x10 GBASE-LR Easy migration to higher speed applications. More information about the different applications can be found in the product information or in the product profile under Data sheets. Properties PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Installation protection: The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable. Connector type: OCTO Trunk cables: MTP® OCTO 4+4 fiber male Polarity: OCTO Trunk cables: TIA Method B „1 to 12“ Fiber types: Multimode OM4 bend-insensitive Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol Product label with serial number at both sides Benefits MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel Fast and safe installation trough factory assembled plug & play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components

€466.17 (excl. VAT)
Fiber optic trunk cable breakout 96 fibers singlemode OS2, MTP®-OCTO-PC-m/ MTP®-OCTO-PC-m, I-F(ZN)HH
PreCONNECT® OCTO MTP® Breakout Trunk cable Applications MTP® (MPO) based data center cabling with 8 fibers per MTP® channel. Optimized for parallel optics MPO 4+4 fiber applications: 40/100/200 GBASE-SR4 400GBASE-SR4.2 BiDi 4x16, 4x32 and 4x64 GFC 100GBASE DR4/PSM4 200GBASE-DR4 400GBASE-DR4 4x10 GBASE-LR Easy migration to higher speed applications. More information about the different applications can be found in the product information or in the product profile under Data sheets. Properties PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Installation protection: The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable. Connector type: OCTO Trunk cables: MTP® OCTO 4+4 fiber male Polarity: OCTO Trunk cables: TIA Method B „1 to 12“ Fiber types: Multimode OM4 bend-insensitive Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol Product label with serial number at both sides Benefits MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel Fast and safe installation trough factory assembled plug & play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components

€1,292.06 (excl. VAT)
Fiber optic trunk cable breakout 8 fibers singlemode OS2, MTP®-OCTO-PC-m/ MTP®-OCTO-PC-m, I-F(ZN)H(ZN)H
PreCONNECT® OCTO MTP® Breakout Trunk cable Applications MTP® (MPO) based data center cabling with 8 fibers per MTP® channel. Optimized for parallel optics MPO 4+4 fiber applications: 40/100/200 GBASE-SR4 400GBASE-SR4.2 BiDi 4x16, 4x32 and 4x64 GFC 100GBASE DR4/PSM4 200GBASE-DR4 400GBASE-DR4 4x10 GBASE-LR Easy migration to higher speed applications. More information about the different applications can be found in the product information or in the product profile under Data sheets. Properties PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Installation protection: The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable. Connector type: OCTO Trunk cables: MTP® OCTO 4+4 fiber male Polarity: OCTO Trunk cables: TIA Method B „1 to 12“ Fiber types: Multimode OM4 bend-insensitive Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol Product label with serial number at both sides Benefits MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel Fast and safe installation trough factory assembled plug & play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components

€160.84 (excl. VAT)
Fiber optic trunk cable breakout 64 fibers singlemode OS2, MTP®-OCTO-PC-m/ MTP®-OCTO-PC-m, I-F(ZN)HH
PreCONNECT® OCTO MTP® Breakout Trunk cable Applications MTP® (MPO) based data center cabling with 8 fibers per MTP® channel. Optimized for parallel optics MPO 4+4 fiber applications: 40/100/200 GBASE-SR4 400GBASE-SR4.2 BiDi 4x16, 4x32 and 4x64 GFC 100GBASE DR4/PSM4 200GBASE-DR4 400GBASE-DR4 4x10 GBASE-LR Easy migration to higher speed applications. More information about the different applications can be found in the product information or in the product profile under Data sheets. Properties PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Installation protection: The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable. Connector type: OCTO Trunk cables: MTP® OCTO 4+4 fiber male Polarity: OCTO Trunk cables: TIA Method B „1 to 12“ Fiber types: Multimode OM4 bend-insensitive Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol Product label with serial number at both sides Benefits MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel Fast and safe installation trough factory assembled plug & play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components

€873.95 (excl. VAT)