No minimum order value
easy and quick ordering
Free delivery within the EU
for orders more than 100 €
5-years-guarantee
on all Rosenberger products
Directly from the manufacturer
at osi.rosenberger.shop

Fiber optic patch cord duplex singlemode OS2, CS-PC/CS-PC, I-V(ZN)H rund 2,0 mm, with CS EZ-Flip, 2,0m

High quality fiber optic fiber patch cord duplex with CS-PC EZ-Flip connector, polarity crossed and changeable, FRNC indoor cable round 2,0 mm, I-V(ZN)H 2E9/125µ yellow, G657.A1 bend insensitive, 2,0m.

€30.80 * (excl. VAT)

Delivery time within 1 weeks

Länge (m):
You can order from 1m to 50m in 0.5m steps
* Price for first 1m €30.80 than after every 1m is €0.37
Product number: 094A0001G657A1-2000

Fiber Optic Patch Cords

Applications

Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request.

Properties

Connector types:

According to IEC 61754-x, for more connector specifications see data sheet.

  • SC: IEC 61754-4
  • MTP®: IEC 61754-7
  • E2000®: IEC 61754-15
  • LC: IEC 61754-20

Polarity:

  • Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173
  • Half duplex cables with duplex/simplex connectors „uncrossed“
  • Duplex cables with simplex connectors on both sides „uncrossed“

Fiber types:

According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.

  • OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
  • OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
  • OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
  • OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1

Cable types:

FRNC-LSZH cable, for more cable specifications see data sheet.

Scope of delivery and packaging:

Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length.

Length tolerance:

Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

Allgemein: General
Betriebstemperatur: -10°C to +60°C
Kabel-Mantelmaterial: FRNC-LSZH
Kern- / Manteldurchmesser: 9/125µm
Polarität: crossed
Produktlinie: Fiber Optic Patch Cord
Stecker: side A / side B
cable type: Single jacket round
channels/fibers: 1 / 2
connector types: CS / CS
fiber type: singlemode bend insensitive

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Lässt sich verbinden mit:

Fiber optic trunk cable breakout 8 fibers singlemode OS2, LC-PC/LC-PC, I-V(ZN)HH, with LC Compact
PreCONNECT® BREAKOUT Applications Data centers and their IT rooms, data center containers and EDGE computing sites. Universal to use fiber optic cabling system up to 24 fibers per trunk Cost and attenuation optimized Focused on a practical and necessary approach We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads. Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables. More information about the different applications can be found in separates product information. Properties PreCONNECT® BREAKOUT Trunk cable: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Cable ends can be assembled with „variable“ long or "stepped" connector legs. Installation protection: The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. MTP®: IEC 61754-7 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Most cost-effective solution for trunks up to 24 fibers and short lengths Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€147.44 (excl. VAT)
Fiber optic trunk cable breakout 12 fibers singlemode OS2, LC-PC/LC-PC, I-V(ZN)HH, with LC Compact
PreCONNECT® BREAKOUT Applications Data centers and their IT rooms, data center containers and EDGE computing sites. Universal to use fiber optic cabling system up to 24 fibers per trunk Cost and attenuation optimized Focused on a practical and necessary approach We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads. Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables. More information about the different applications can be found in separates product information. Properties PreCONNECT® BREAKOUT Trunk cable: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Cable ends can be assembled with „variable“ long or "stepped" connector legs. Installation protection: The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. MTP®: IEC 61754-7 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Most cost-effective solution for trunks up to 24 fibers and short lengths Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.

Variants from €161.91*
€168.39 (excl. VAT)
Fiber optic trunk cable 72 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNK Applications Infrastructure cabling within data centers, office buildings and campus. Universal fiber optic system Cost and attenuation optimized Focused on a practical and necessary approach For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/. Properties PreCONNECT® Standard Trunk cables: Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers. The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables. Installation protection: The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€1,617.29 (excl. VAT)
Fiber optic trunk cable 48 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€1,167.22 (excl. VAT)
Fiber optic trunk cable 144 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€4,053.84 (excl. VAT)
SMAP-G2 HD 1/3 HU part front plate with 6/6 width partition, LC-Duplex singlemode OS2 blue
SMAP-G2 HD 1/3 HU 1/6 part front plates with matrix numbering Applications SMAP-G2 HD empty panels with 6/6 width partition Properties The PFPs are toolless inserted from the front side and fixed with quick fasteners. By this design they can be pulled out to the front for maintenance. The numbering of the part front plates PFP is a modular numerical matrix. The LC-Duplex and MTP® ports within the PFPs have a fixed 1 to 4 labeling. The PFPs can be numbered with their positions they have within the panels with the exchangeable numbering clips the panels are shipped with. Material and color: Steel powder coated RAL9005 black Adapter types per PFP: 1 LC8 = 4 LC-Duplex ports 2 MTP®-Duplex = 4 MTP® ports Adapter variants: LC8: OM4 violet, SM blue MTP® multimode: TIA type B „aligned centered keys“ „1 to 12“ grey MTP® singlemode: TIA type A “opposed centered keys” „1 to 1“ green Scope of delivery and packaging: Part front plate fully factory-assembled in carton

€17.18 (excl. VAT)
Fiber optic trunk cable 24 fibers singlemode OS2, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€510.01 (excl. VAT)
SMAP-G2 HD Port-Breakout-Unit, 1/3 HE with 6/6 width partition, MTP-LC, OCTO 8 fibres, singlemode OS2
SMAP-G2 HD 8 fiber MTP-LC Port-Breakout-Unit Applications For installation in SMAP-G2 HD panel with 6/6 width partition Properties 1x MTP®4+4 OCTO female connector at cable pigtail 4 LC-Duplex ports at the front side Toolless placement of the module cassettes into the panel from the front side, fixing with quick fasteners Material and color: Cassette body and front: aluminum powder coated RAL9005 black Adapter types: Front side: 1 LC8 = 4 LC-Duplex ports Adapter variants: MTP® multimode: TIA type B „aligned centered keys“ „1 to 12“ grey MTP® singlemode: TIA type A “opposed centered keys” „1 to 1“ green LC8: OM4 violet, SM blue Number of fibers: 8 Scope of delivery and packaging: Port-Breakout-Unit panel fully factory-assembled in carton Adapters mounted

€168.63 (excl. VAT)
Fiber optic trunk cable breakout 24 fibers singlemode OS2, LC-PC/LC-PC, I-V(ZN)HH, with LC Compact
PreCONNECT® BREAKOUT Applications Data centers and their IT rooms, data center containers and EDGE computing sites. Universal to use fiber optic cabling system up to 24 fibers per trunk Cost and attenuation optimized Focused on a practical and necessary approach We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads. Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables. More information about the different applications can be found in separates product information. Properties PreCONNECT® BREAKOUT Trunk cable: Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables. Cable ends can be assembled with „variable“ long or "stepped" connector legs. Installation protection: The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. MTP®: IEC 61754-7 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Most cost-effective solution for trunks up to 24 fibers and short lengths Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€313.80 (excl. VAT)
Fiber optic trunk cable 12 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNK Applications Infrastructure cabling within data centers, office buildings and campus. Universal fiber optic system Cost and attenuation optimized Focused on a practical and necessary approach For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/. Properties PreCONNECT® Standard Trunk cables: Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers. The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables. Installation protection: The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€345.42 (excl. VAT)
Fiber optic trunk cable 96 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€2,751.72 (excl. VAT)
SMAP-G2 HD 1/3 HU part front plate with 6/6 width partition, LC-Duplex multimode OM4 violett
SMAP-G2 HD 1/3 HU 1/6 part front plates with matrix numbering Applications SMAP-G2 HD empty panels with 6/6 width partition Properties The PFPs are toolless inserted from the front side and fixed with quick fasteners. By this design they can be pulled out to the front for maintenance. The numbering of the part front plates PFP is a modular numerical matrix. The LC-Duplex and MTP® ports within the PFPs have a fixed 1 to 4 labeling. The PFPs can be numbered with their positions they have within the panels with the exchangeable numbering clips the panels are shipped with. Material and color: Steel powder coated RAL9005 black Adapter types per PFP: 1 LC8 = 4 LC-Duplex ports 2 MTP®-Duplex = 4 MTP® ports Adapter variants: LC8: OM4 violet, SM blue MTP® multimode: TIA type B „aligned centered keys“ „1 to 12“ grey MTP® singlemode: TIA type A “opposed centered keys” „1 to 1“ green Scope of delivery and packaging: Part front plate fully factory-assembled in carton

€17.15 (excl. VAT)
Fiber optic trunk cable 12 fibers singlemode OS2, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€328.91 (excl. VAT)
SMAP-G2 HD MTP module cassettes 1/3 HE with 6/6 width partition, 8 fibres, LC-Duplex / MTP OCTO singlemode fitting for PreCONNECT® OCTO trunks
SMAP-G2 HD 8 fiber MTP-LC module cassettes Applications For Port-Breakout of PreCONNECT® OCTO trunks with MTP® connectors Fitting in SMAP-G2 HD panel with 6/6 width partition Properties 1x MTP® female port 4+4F OCTO at the rear side 4 LC-Duplex ports at the front side Toolless placement of the module cassettes into the panel from the front side, fixing with quick fasteners Material and color: Cassette body and front: aluminum powder coated RAL9005 black Adapter types: Rear side: 1 MTP® Front side: 1 LC8 = 4 LC-Duplex ports Adapter variants: MTP® multimode: TIA type B „aligned centered keys“ „1 to 12“ grey MTP® singlemode: TIA type A “opposed centered keys” „1 to 1“ green LC8: OM4 violet, SM blue Number of fibers: 8 Scope of delivery and packaging: Module cassettes fully factory-assembled in carton Adapters mounted

€130.06 (excl. VAT)
Fiber optic trunk cable 48 fibers singlemode OS2, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€1,167.22 (excl. VAT)