FO trunks with singlemode and multimode OM3 and OM4 fibers, factory assembled with the common FO connectors LC, SC, E2000®, MTP®, SN®, MDC, CS®
etc. for indoor applications (e.g. data center, building). Based on multifiber FRNC-LSZH installation cables with CPR certification, I-B cables are with additional rodent protection.
PreCONNECT® STANDARD TRUNK
Applications
Infrastructure cabling within data centers, office buildings and campus.
Universal fiber optic system
Cost and attenuation optimized
Focused on a practical and necessary approach
For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.
Properties
PreCONNECT® Standard Trunk cables:
Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.
The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
SC: IEC 61754-4
MTP®: IEC 61754-7
E2000®: IEC 61754-15
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNK
Applications
Infrastructure cabling within data centers, office buildings and campus.
Universal fiber optic system
Cost and attenuation optimized
Focused on a practical and necessary approach
For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.
Properties
PreCONNECT® Standard Trunk cables:
Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.
The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
SC: IEC 61754-4
MTP®: IEC 61754-7
E2000®: IEC 61754-15
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNK
Applications
Infrastructure cabling within data centers, office buildings and campus.
Universal fiber optic system
Cost and attenuation optimized
Focused on a practical and necessary approach
For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.
Properties
PreCONNECT® Standard Trunk cables:
Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.
The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
SC: IEC 61754-4
MTP®: IEC 61754-7
E2000®: IEC 61754-15
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNK
Applications
Infrastructure cabling within data centers, office buildings and campus.
Universal fiber optic system
Cost and attenuation optimized
Focused on a practical and necessary approach
For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.
Properties
PreCONNECT® Standard Trunk cables:
Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.
The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
SC: IEC 61754-4
MTP®: IEC 61754-7
E2000®: IEC 61754-15
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® BREAKOUTApplicationsData centers and their IT rooms, data center containers and EDGE computing sites.Universal to use fiber optic cabling system up to 24 fibers per trunkCost and attenuation optimizedFocused on a practical and necessary approachWe see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads. Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables. More information about the different applications can be found in separates product information.PropertiesPreCONNECT® BREAKOUT Trunk cable:Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.Cable ends can be assembled with „variable“ long or "stepped" connector legs.Installation protection:The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.MTP®: IEC 61754-7LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsMost cost-effective solution for trunks up to 24 fibers and short lengthsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® BREAKOUT
Applications
Data centers and their IT rooms, data center containers and EDGE computing sites.
Universal to use fiber optic cabling system up to 24 fibers per trunk
Cost and attenuation optimized
Focused on a practical and necessary approach
We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads.
Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables.
More information about the different applications can be found in separates product information.
Properties
PreCONNECT® BREAKOUT Trunk cable:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Cable ends can be assembled with „variable“ long or "stepped" connector legs.
Installation protection:
The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
MTP®: IEC 61754-7
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Most cost-effective solution for trunks up to 24 fibers and short lengths
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® BREAKOUT
Applications
Data centers and their IT rooms, data center containers and EDGE computing sites.
Universal to use fiber optic cabling system up to 24 fibers per trunk
Cost and attenuation optimized
Focused on a practical and necessary approach
We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads.
Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables.
More information about the different applications can be found in separates product information.
Properties
PreCONNECT® BREAKOUT Trunk cable:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Cable ends can be assembled with „variable“ long or "stepped" connector legs.
Installation protection:
The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
MTP®: IEC 61754-7
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Most cost-effective solution for trunks up to 24 fibers and short lengths
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® BREAKOUT
Applications
Data centers and their IT rooms, data center containers and EDGE computing sites.
Universal to use fiber optic cabling system up to 24 fibers per trunk
Cost and attenuation optimized
Focused on a practical and necessary approach
We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads.
Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables.
More information about the different applications can be found in separates product information.
Properties
PreCONNECT® BREAKOUT Trunk cable:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Cable ends can be assembled with „variable“ long or "stepped" connector legs.
Installation protection:
The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
MTP®: IEC 61754-7
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Most cost-effective solution for trunks up to 24 fibers and short lengths
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® BREAKOUT
Applications
Data centers and their IT rooms, data center containers and EDGE computing sites.
Universal to use fiber optic cabling system up to 24 fibers per trunk
Cost and attenuation optimized
Focused on a practical and necessary approach
We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads.
Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables.
More information about the different applications can be found in separates product information.
Properties
PreCONNECT® BREAKOUT Trunk cable:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Cable ends can be assembled with „variable“ long or "stepped" connector legs.
Installation protection:
The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
MTP®: IEC 61754-7
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Most cost-effective solution for trunks up to 24 fibers and short lengths
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® BREAKOUT
Applications
Data centers and their IT rooms, data center containers and EDGE computing sites.
Universal to use fiber optic cabling system up to 24 fibers per trunk
Cost and attenuation optimized
Focused on a practical and necessary approach
We see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads.
Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables.
More information about the different applications can be found in separates product information.
Properties
PreCONNECT® BREAKOUT Trunk cable:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Cable ends can be assembled with „variable“ long or "stepped" connector legs.
Installation protection:
The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.
Connector types:
According to IEC 61754-x, for more connector specifications see data sheet.
MTP®: IEC 61754-7
LC: IEC 61754-20
Polarity:
The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.
Fiber types:
According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.
OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1
Cable type:
FRNC-LSZH cable, for more cable specifications see data sheet.
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.
Benefits
Most cost-effective solution for trunks up to 24 fibers and short lengths
Fast and safe installation trough factory assembled Plug & Play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
PreCONNECT® OCTO MTP® Breakout Trunk cable
Applications
MTP® (MPO) based data center cabling with 8 fibers per MTP® channel.
Optimized for parallel optics MPO 4+4 fiber applications:
40/100/200 GBASE-SR4
400GBASE-SR4.2 BiDi
4x16, 4x32 and 4x64 GFC
100GBASE DR4/PSM4
200GBASE-DR4
400GBASE-DR4
4x10 GBASE-LR
Easy migration to higher speed applications.
More information about the different applications can be found in the product information or in the product profile under Data sheets.
Properties
PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable.
Connector type:
OCTO Trunk cables: MTP® OCTO 4+4 fiber male
Polarity:
OCTO Trunk cables: TIA Method B „1 to 12“
Fiber types:
Multimode OM4 bend-insensitive
Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum
Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol
Product label with serial number at both sides
Benefits
MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications
Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel
Fast and safe installation trough factory assembled plug & play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components
PreCONNECT® OCTO MTP® Breakout Trunk cable
Applications
MTP® (MPO) based data center cabling with 8 fibers per MTP® channel.
Optimized for parallel optics MPO 4+4 fiber applications:
40/100/200 GBASE-SR4
400GBASE-SR4.2 BiDi
4x16, 4x32 and 4x64 GFC
100GBASE DR4/PSM4
200GBASE-DR4
400GBASE-DR4
4x10 GBASE-LR
Easy migration to higher speed applications.
More information about the different applications can be found in the product information or in the product profile under Data sheets.
Properties
PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable.
Connector type:
OCTO Trunk cables: MTP® OCTO 4+4 fiber male
Polarity:
OCTO Trunk cables: TIA Method B „1 to 12“
Fiber types:
Multimode OM4 bend-insensitive
Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum
Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol
Product label with serial number at both sides
Benefits
MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications
Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel
Fast and safe installation trough factory assembled plug & play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components
PreCONNECT® OCTO MTP® Breakout Trunk cable
Applications
MTP® (MPO) based data center cabling with 8 fibers per MTP® channel.
Optimized for parallel optics MPO 4+4 fiber applications:
40/100/200 GBASE-SR4
400GBASE-SR4.2 BiDi
4x16, 4x32 and 4x64 GFC
100GBASE DR4/PSM4
200GBASE-DR4
400GBASE-DR4
4x10 GBASE-LR
Easy migration to higher speed applications.
More information about the different applications can be found in the product information or in the product profile under Data sheets.
Properties
PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable.
Connector type:
OCTO Trunk cables: MTP® OCTO 4+4 fiber male
Polarity:
OCTO Trunk cables: TIA Method B „1 to 12“
Fiber types:
Multimode OM4 bend-insensitive
Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum
Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol
Product label with serial number at both sides
Benefits
MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications
Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel
Fast and safe installation trough factory assembled plug & play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components
PreCONNECT® OCTO MTP® Breakout Trunk cable
Applications
MTP® (MPO) based data center cabling with 8 fibers per MTP® channel.
Optimized for parallel optics MPO 4+4 fiber applications:
40/100/200 GBASE-SR4
400GBASE-SR4.2 BiDi
4x16, 4x32 and 4x64 GFC
100GBASE DR4/PSM4
200GBASE-DR4
400GBASE-DR4
4x10 GBASE-LR
Easy migration to higher speed applications.
More information about the different applications can be found in the product information or in the product profile under Data sheets.
Properties
PreCONNECT® OCTO Breakout Trunk cables with I-F(ZN)HH breakout cables:
Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.
Installation protection:
The trunk connector legs are fitting for the 19“ panel systems and are packed in non-pull resistant dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installation tubes deliverable.
Connector type:
OCTO Trunk cables: MTP® OCTO 4+4 fiber male
Polarity:
OCTO Trunk cables: TIA Method B „1 to 12“
Fiber types:
Multimode OM4 bend-insensitive
Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D
Length definition:
Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® square-interfaces.
Scope of delivery and packaging:
Dependent on the length as cable ring or on cardboard or wooden drum
Insertion loss and return loss measured acc. to IEC 61300-3-4, method B, MM 850/1300nm and SM 1310/1550nm, with measurement protocol
Product label with serial number at both sides
Benefits
MTP® cabling system perfectly fitting for SR4 and DR4/PSM4 applications
Cost reduction through the only for SR4 and DR4/PSM4 needed 8 fibers instead of the so far usual 12 are in one MTP® channel
Fast and safe installation trough factory assembled plug & play systematic
Highest quality and cost-efficiency through factory assembling
PreCONNECT® cabling systems consist of perfectly harmonized modular single components