FO trunks are multifiber FO installation cables, pre-assembled with the common FO connectors LC, SC, E2000®, MTP®, SN®, MDC, CS® etc.
for fast and secure installation of FO links (often Plug&Play called).
Rosenberger OSI brought already 1991 high fibercount factory assembled FO trunk cables to the markt. We are offering FO trunks withsinglemodeand multimode OM3 and OM4 fibersfor indoor applications (e.g. data center, building) as well asfor universal applications (e.g. building, campus, factory) to you in this webshop.
Individual lengths and other than the offered configuration on request.
Do you need help?
Thelephone support under:
+49(821)24924-1000
email:
webshop-osi@rosenberger.com
Filter products
Fiber optic trunk cable 12 fibers multimode OM4, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNK Applications Infrastructure cabling within data centers, office buildings and campus. Universal fiber optic system Cost and attenuation optimized Focused on a practical and necessary approach For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/. Properties PreCONNECT® Standard Trunk cables: Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers. The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables. Installation protection: The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€347.65 (excl. VAT)
Fiber optic trunk cable 12 fibers multimode OM4, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€347.72 (excl. VAT)
Fiber optic trunk cable 12 fibers multimode OM4, SC-PC/SC-PC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€366.25 (excl. VAT)
Fiber optic trunk cable 12 fibers singlemode OS2, E2000®-APC/E2000®-APC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€651.15 (excl. VAT)
Fiber optic trunk cable 12 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNK Applications Infrastructure cabling within data centers, office buildings and campus. Universal fiber optic system Cost and attenuation optimized Focused on a practical and necessary approach For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/. Properties PreCONNECT® Standard Trunk cables: Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers. The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables. Installation protection: The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€348.06 (excl. VAT)
Fiber optic trunk cable 12 fibers singlemode OS2, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€364.97 (excl. VAT)
Fiber optic trunk cable 12 fibers singlemode OS2, SC-PC/SC-PC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€383.88 (excl. VAT)
Fiber optic trunk cable 144 fibers multimode OM4, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€4,018.39 (excl. VAT)
Fiber optic trunk cable 144 fibers multimode OM4, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€4,157.48 (excl. VAT)
Fiber optic trunk cable 144 fibers multimode OM4, SC-PC/SC-PC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€4,610.50 (excl. VAT)
Fiber optic trunk cable 144 fibers singlemode OS2, E2000®-APC/E2000®-APC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€9,297.28 (excl. VAT)
Fiber optic trunk cable 144 fibers singlemode OS2, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€4,232.38 (excl. VAT)
Fiber optic trunk cable 144 fibers singlemode OS2, SC-PC/SC-PC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€4,548.40 (excl. VAT)
Fiber optic trunk cable 24 fibers multimode OM4, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€549.68 (excl. VAT)
Fiber optic trunk cable 24 fibers multimode OM4, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€554.19 (excl. VAT)
Fiber optic trunk cable 24 fibers multimode OM4, SC-PC/SC-PC, I-B(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€591.64 (excl. VAT)
Fiber optic trunk cable 24 fibers multimode OM4, SC-PC/SC-PC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€575.10 (excl. VAT)
Fiber optic trunk cable 24 fibers singlemode OS2, E2000®-APC/E2000®-APC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€1,161.49 (excl. VAT)
Fiber optic trunk cable 24 fibers singlemode OS2, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€555.17 (excl. VAT)
Fiber optic trunk cable 24 fibers singlemode OS2, SC-PC/SC-PC, I-B(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€593.05 (excl. VAT)
Fiber optic trunk cable 48 fibers multimode OM4, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€1,108.40 (excl. VAT)
Fiber optic trunk cable 48 fibers multimode OM4, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€1,108.40 (excl. VAT)
Fiber optic trunk cable 48 fibers multimode OM4, SC-PC/SC-PC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€1,329.33 (excl. VAT)
Fiber optic trunk cable 48 fibers singlemode OS2, E2000®-APC/E2000®-APC, U-DQ(ZN)BH
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.
€2,620.40 (excl. VAT)