No minimum order value
easy and quick ordering
Free delivery within the EU
for orders more than 100 €
5-years-guarantee
on all Rosenberger products
Directly from the manufacturer
at osi.rosenberger.shop

Fiber optic patch cord duplex multimode OM3, LC-PC/LC-PC, I-V(ZN)H rund 2,8 mm, with LC Compact

High quality fiber optic fiber patch cord duplex with LC-PC Compact connector, polarity crossed and changeable, FRNC indoor cable round 2,8 mm, I-(V(ZN)H 2G50/125µ aqua, OM3 bend insensitive.

Price before €13.26 (excl. VAT)
Now just €6.63 * (excl. VAT)

In Stock: 100

Available, delivery time: 1-3 days

Length in stock
Product number: 087A6601OM3.1000

Fiber Optic Patch Cords

Applications

Patch cords suitable for cabling in data centers and office buildings. Patch cords for mobile communications, industrial application available on request.

Properties

Connector types:

According to IEC 61754-x, for more connector specifications see data sheet.

  • SC: IEC 61754-4
  • MTP®: IEC 61754-7
  • E2000®: IEC 61754-15
  • LC: IEC 61754-20

Polarity:

  • Full duplex cables with duplex connectors on both sides “crossed” in according with ISO/IEC 11801 und EN 50173
  • Half duplex cables with duplex/simplex connectors „uncrossed“
  • Duplex cables with simplex connectors on both sides „uncrossed“

Fiber types:

According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.

  • OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
  • OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
  • OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
  • OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1

Cable types:

FRNC-LSZH cable, for more cable specifications see data sheet.

Scope of delivery and packaging:

Factory-measured attenuation report according to IEC 61300-3-4, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number labels at the cable ends for network documentation, product ID label on each packaging.Individually packed dust protected in foil bags, as of a length of 100m on cardboard drum, available in any standard length.

Length tolerance:

Up to 1 m = -50 mm, 2 m to 3 m = -100 mm, 4 m to 25 m = -200 mm, longer than 25 m

Allgemein: General
Betriebstemperatur: -10°C to +60°C
Faser:
Kabel:
Kabel-Mantelmaterial: FRNC-LSZH
Kern- / Manteldurchmesser: 50/125µm
Polarität: crossed
Produktlinie: Fiber Optic Patch Cord
Stecker: side A / side B
cable type: Single jacket round
channels/fibers: 1 / 2
connector types: LC-PC / LC-PC
fiber type: Multimode G50/125 OM3

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Lässt sich verbinden mit:

Fiber optic trunk cable 24 fibers multimode OM3, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€519.37 (excl. VAT)
19" Fiber optic distribution panel 48 fibers multimode OM3, LC/LC duplex, telescopic complete pullout 1 HU
19" Fiber Optic Distribution Panel Applications For installation in 19" racks Distribution, for example, of PreCONNECT® STANDARD trunk cables to patch cords Properties Suitable for installation of assembled trunk cables Available in two variants, fixed installation or telescopic complete pullout fully retractable Torsion and strain-resistant cable clatch for 2 PreCONNECT® trunk cable dividers for 1 HU and 4 PreCONNECT® trunk cable dividers for 2 HU 2 PG 21 (29 mm) cable inputs Oblique 45° cable guide to rear, guide direction selectable 2 universal cable clatches for simplex, duplex and breakout cables can be mounted Screen printed front panel labelling: numeric and alphanumeric Material and color: Body aluminium, natural Front power-coated aluminium, RAL 7035 (light gray) Adapter types: SC-Duplex LC-Duplex Adapter variants: Multimode (OM3, OM4, OM5) Singlemode (OS2) Number of fibers: 12, 24, 48, 96 Scope of delivery and packaging: Distribution panel fully factory-assembled in carton Adapters mounted Blind cover in unused cable inputs Blind cover in unused front panel ports

€161.56 (excl. VAT)
Fiber optic trunk cable 48 fibers multimode OM3, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€1,184.31 (excl. VAT)
Fiber optic trunk cable 144 fibers multimode OM3, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€4,104.46 (excl. VAT)
Fiber optic trunk cable 12 fibers multimode OM3, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€333.92 (excl. VAT)
Fiber optic trunk cable 48 fibers multimode OM3, LC-PC/LC-PC, U-DQ(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNK Applications Infrastructure cabling within data centers, office buildings and campus. Universal fiber optic system Cost and attenuation optimized Focused on a practical and necessary approach For further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/. Properties PreCONNECT® Standard Trunk cables: Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers. The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables. Installation protection: The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable. Connector types: According to IEC 61754-x, for more connector specifications see data sheet. SC: IEC 61754-4 MTP®: IEC 61754-7 E2000®: IEC 61754-15 LC: IEC 61754-20 Polarity: The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable. Fiber types: According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet. OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1 OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1 OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1 OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1 Cable type: FRNC-LSZH cable, for more cable specifications see data sheet. Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers. Scope of delivery and packaging: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length. Benefits Fast and safe installation trough factory assembled Plug & Play systematic Highest quality and cost-efficiency through factory assembling PreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€1,184.31 (excl. VAT)
Fiber optic trunk cable breakout 12 fibers multimode OM3, LC-PC/LC-PC, I-V(ZN)HH, with LC Compact
PreCONNECT® BREAKOUTApplicationsData centers and their IT rooms, data center containers and EDGE computing sites.Universal to use fiber optic cabling system up to 24 fibers per trunkCost and attenuation optimizedFocused on a practical and necessary approachWe see breakout trunk cables for short lengths and up to 24 fibers as an alternative product to our proven loose tube cable-based trunk cables with distribution heads. Breakout trunk cables do not require distribution heads, since the connectors are directly assembled on the robust sub-elements of the breakout cables. More information about the different applications can be found in separates product information.PropertiesPreCONNECT® BREAKOUT Trunk cable:Breakout trunk cable have PreCONNECT® square-interfaces on both sides which can be tool-less hooked into the 19” panel systems for tensile and torsion resistant fixing of the trunk cables.Cable ends can be assembled with „variable“ long or "stepped" connector legs.Installation protection:The connector legs are packed in a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in indoor IP50 dustproof, 150 N tensile, step and kink resistant, installation tubes.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.MTP®: IEC 61754-7LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsMost cost-effective solution for trunks up to 24 fibers and short lengthsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

Variants from €170.43*
€177.25 (excl. VAT)
19" Fiber optic distribution panel 96 fibers multimode OM3, LC/LC duplex, telescopic complete pullout 2 HU
19" Fiber Optic Distribution Panel Applications For installation in 19" racks Distribution, for example, of PreCONNECT® STANDARD trunk cables to patch cords Properties Suitable for installation of assembled trunk cables Available in two variants, fixed installation or telescopic complete pullout fully retractable Torsion and strain-resistant cable clatch for 2 PreCONNECT® trunk cable dividers for 1 HU and 4 PreCONNECT® trunk cable dividers for 2 HU 2 PG 21 (29 mm) cable inputs Oblique 45° cable guide to rear, guide direction selectable 2 universal cable clatches for simplex, duplex and breakout cables can be mounted Screen printed front panel labelling: numeric and alphanumeric Material and color: Body aluminium, natural Front power-coated aluminium, RAL 7035 (light gray) Adapter types: SC-Duplex LC-Duplex Adapter variants: Multimode (OM3, OM4, OM5) Singlemode (OS2) Number of fibers: 12, 24, 48, 96 Scope of delivery and packaging: Distribution panel fully factory-assembled in carton Adapters mounted Blind cover in unused cable inputs Blind cover in unused front panel ports

€272.20 (excl. VAT)
Fiber optic trunk cable 96 fibers multimode OM3, LC-PC/LC-PC, I-B(ZN)BH, with LC Compact
PreCONNECT® STANDARD TRUNKApplicationsInfrastructure cabling within data centers, office buildings and campus.Universal fiber optic systemCost and attenuation optimizedFocused on a practical and necessary approachFor further information on the various applications, see separate product profile at https://osi.rosenberger.com/products-services/fiber-optic-cabling-systems/.PropertiesPreCONNECT® Standard Trunk cables:Cable ends are molded in distribution heads and assembled with „stepped“ connector legs. The used “standard stepping” of the connector legs are suitable for all PreCONNECT® panel systems and for most common panel systems of other manufacturers.The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.Installation protection:The connector legs and cable dividers are packed in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes. Alternatively Indoor IP50 dust-proof or Outdoor IP67 water-proof deliverable.Connector types:According to IEC 61754-x, for more connector specifications see data sheet.SC: IEC 61754-4MTP®: IEC 61754-7E2000®: IEC 61754-15LC: IEC 61754-20Polarity:The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.Fiber types:According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1Cable type:FRNC-LSZH cable, for more cable specifications see data sheet.Length definition:Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.Scope of delivery and packaging:Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both cable ends for network documentation, Product ID label on each packaging, including installation manual, available in any standard length.BenefitsFast and safe installation trough factory assembled Plug & Play systematicHighest quality and cost-efficiency through factory assemblingPreCONNECT® cabling systems consist of perfectly harmonized modular single components.

€2,785.92 (excl. VAT)