Fiber optic trunk cable multijumper 48 fibers singlemode OS2, SC-PC/SC-PC, U-DQ(ZN)BH

Product information "Fiber optic trunk cable multijumper 48 fibers singlemode OS2, SC-PC/SC-PC, U-DQ(ZN)BH"

PreCONNECT® TRUNK MULTIJUMPER

Applications

Cabling of large switches and floor-standing IT hardware within data centers, to represent their ports in a patch location.

  • Trunk Multijumper up to 144 fibers per trunk
  • Cost and attenuation optimized
  • Focused on a practical and necessary approach

More information about the different applications can be found in the separates product information.

Properties

PreCONNECT® MULTIJUMPER Trunk cable:

Cable ends are molded in distribution heads and assembled with „variable“ long or "stepped" connector legs.

The PreCONNECT® cable divider is a mechanically and thermally robust and splice-less cable divider for fiber separation of loose tube cables. With its integrated PreCONNECT® square interface, the cable divider can be tool-less hooked into PreCONNECT® panels for tensile and torsion resistant fixing of the trunk cables.

Installation protection:

The connector legs and cable dividers are packed in with a non pull resistant dustproof foil tube. Stepped connector legs can be packed optionally in 600 N tensile strength, crush resistant, kink and torsion resistant, installation tubes.

Connector types:

According to IEC 61754-x, for more connector specifications see data sheet.

  • SC: IEC 61754-4
  • MTP®: IEC 61754-7
  • E2000®: IEC 61754-15
  • LC: IEC 61754-20

Polarity:

The connector legs are alphanumerically uniquely coded. The standard polarity is „channel-wise crossed“ (pairwise flipped) for full-duplex transmission systems – A1 to B1, A2 to B2, etc. On request „uncrossed“ deliverable.

Fiber types:

According to ISO/IEC 11801, EN 50173-1, IEC 60793-2-x and ITUG65x, for more fiber specifications see data sheet.

  • OM3: IEC 60793-2-10 type A1a.2, ITU G.651.1
  • OM4: IEC 60793-2-10 type A1a.3, ITU G.651.1
  • OM5: IEC 60793-2-10 type A1a.4, ITU G.651.1
  • OS2: IEC 60793-2-50 type B1.3, ITU G.657.A1

Cable type:

FRNC-LSZH cable, for more cable specifications see data sheet.

Length definition:

Order-length = length between the connectors of the longest legs at both sides, not between the PreCONNECT® cable dividers.

Scope of delivery and packaging:

Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, measurement values on request or via our website: https://www.rosenberger.com/en/downloads/mdm.php. Serial number on both sides of cable ends for network documentation, Product ID label on each packaging, including installation manual available in any standard length.

Benefits

  • Cost reduction through direct attach of the IT Hardware Transceivers to the TMJ connector legs
  • Most cost-effective solution for trunks up to 24 fibers and short lengths
  • Attenuation reduction through the saving of one connection in the transmission channel
  • Application specific individually configurable
  • Fast and safe installation trough factory assembled Plug & Play systematic
  • Highest quality and cost-efficiency through factory assembling
  • PreCONNECT® cabling systems consist of perfectly harmonized modular single components.
CPR class cable: Eca
Fiber chart: crossed channel-wise
cable jacket: FRNC-LSZH
cable type: U-DQ(ZN)BH nxm...
channels/fibers: 24 / 48
connector types: SC-PC / SC-PC
core / jacket diameter: 9/125µm
fiber type: Singlemode E9/125
operating temprature: -10°C to +60°C
product line: PreCONNECT® TRUNK MULTIJUMPER